Significance The SARS-COV-2 virus, which causes the Covid-19 pandemic, can bind to epithelial cells in the human cornea and conjunctiva which may result in changes of corneal and lenticular densitometry Purpose We aimed to report the corneal and lenticular clarity of patients who had been diagnosed previously with confirmed infection of COVID-19. Methods This was a prospective, cross-sectional study. Fifty-three patients who had recovered from COVID-19 and 51 healthy individuals who had not had COVID-19 (control) were included in this study. Measurement of the corneal (at a corneal diameter of 12-mm) and lens densitometry of participants were performed using a Pentacam HR Scheimpflug imaging system. Three different optimal depths as anterior, central and posterior layers and four concentric zones, comprised of diameters of 0 to 2, 2 to 6, 6 to 10, and 10 to12 mm were chosen to perform the corneal densitometric measurements. The mean lenticular densitometric values were calculated in Zone 1 at 2.0 mm, Zone 2 at 4.0 mm, and Zone 3 at 6.0 mm by taking the central part of the pupil as reference point. Results When compared with the individuals in the control group, the corneal densitometry measurements in the patients in the COVID-19 group were considerably higher in the zones at anterior 0–2 mm, 2–6 mm, 6-10 mm zones and total diameter; center 0–2 mm, 2–6 mm zones and total diamater; posterior 0–2 mm zone; total corneal 0–2 mm, 2–6 mm zones and total diameter (P < .05, for each). When compared with the individuals in the control group, all of the lens densitometry measurements, except for those located in Zone 1, were determined to be significantly higher among the patients in the COVID-19 group (P < .05, for each). Conclusions Significant alterations were found in corneal and lenticular densitometric values in patients who had had COVID-19. The virus could adversely affect cornea and lens transparency.
Objective Assessment of Corneal and Lens Clarity in patients with COVID-19

Significance The SARS-COV-2 virus, which causes the Covid-19 pandemic, can bind to epithelial cells in the human cornea and conjunctiva which may result in changes of corneal and lenticular densitometry Purpose We aimed to report the corneal and lenticular clarity of patients who had been diagnosed previously with confirmed infection of COVID-19. Methods This was a prospective, cross-sectional study. Fifty-three patients who had recovered from COVID-19 and 51 healthy individuals who had not had COVID-19 (control) were included in this study. Measurement of the corneal (at a corneal diameter of 12-mm) and lens densitometry of participants were performed using a Pentacam HR Scheimpflug imaging system. Three different optimal depths as anterior, central and posterior layers and four concentric zones, comprised of diameters of 0 to 2, 2 to 6, 6 to 10, and 10 to12 mm were chosen to perform the corneal densitometric measurements. The mean lenticular densitometric values were calculated in Zone 1 at 2.0 mm, Zone 2 at 4.0 mm, and Zone 3 at 6.0 mm by taking the central part of the pupil as reference point. Results When compared with the individuals in the control group, the corneal densitometry measurements in the patients in the COVID-19 group were considerably higher in the zones at anterior 0–2 mm, 2–6 mm, 6-10 mm zones and total diameter; center 0–2 mm, 2–6 mm zones and total diamater; posterior 0–2 mm zone; total corneal 0–2 mm, 2–6 mm zones and total diameter (P < .05, for each). When compared with the individuals in the control group, all of the lens densitometry measurements, except for those located in Zone 1, were determined to be significantly higher among the patients in the COVID-19 group (P < .05, for each). Conclusions Significant alterations were found in corneal and lenticular densitometric values in patients who had had COVID-19. The virus could adversely affect cornea and lens transparency.

Etiketler

COVID-19

Yazar Hakkında

Doç. Dr. Yasin Şakir Göker

Doç. Dr. Yasin Şakir Göker

Ankara’da dünyaya geldim ve İlkokulu Ankara’da tamamladım. Orta öğrenimimi Ankara Atatürk Lisesi’nde, Lise öğrenimimi Kuleli Askeri Lisesi’nde tamamladım. Tıp Fakültesinin ilk 5 yılını 2003-2008 yılları arasında Gülhane Askeri Tıp Akademisi Tıp Fakültesi’nde tamamladım. Tıp Fakültesinin 6. yılı olan internlük dönemini Trakya Üniversitesi Tıp fakültesinde tamamlayarak 2009 yılında Tıp Fakültesinden mezun oldum. Ankara Gölbaşı Ertuğrul Gazi Sağlık Ocağı’nda mecburi hizmet görevimi sürdürürken Tıpta uzmanlık sınavında derece ile Türkiye 37. olarak Türkiye’de sadece göz hastalarının muayene olduğu iki göz hastanesinden biri olan SB. Beyoğlu Göz Eğitim ve Araştırma Hastanesi’nde göz hastalıkları ihtisasıma başladım.

Önemli Bilgilendirme

Site içerisinde bulunan bilgiler bilgilendirme amaçlıdır. Bu bilgilendirme kesinlikle hekimin hastasını tıbbi amaçla muayene etmesi veya tanı koyması yerine geçmez.

Benzer Makaleler

Bu uzmanın başka makalesi bulunmamaktadır